Rumah ProdukSerat PP Beton

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building

Sertifikasi
CINA Briture Co., Ltd. Sertifikasi
CINA Briture Co., Ltd. Sertifikasi
I 'm Online Chat Now

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building
Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building

Gambar besar :  Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building

Detail produk:
Tempat asal: Anhui, Tiongkok
Nama merek: None
Sertifikasi: ISO
Nomor model: Jenis hibrida serat pp
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: 1000kg
Harga: USD 2.2-2.80/KGS FOB Shanghai/Qingdao.
Kemasan rincian: Untuk tipe pp fiber hybrid, kemasannya adalah 1kg per kantong PE, 10kg per karung anyaman, 800kg per
Waktu pengiriman: 7-30 hari kerja
Syarat-syarat pembayaran: L/C, T/T
Menyediakan kemampuan: 35000MT/tahun

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building

Deskripsi
Nama Produk: Jenis hibrida serat pp Warna serat: Abu-abu bercampur dengan putih
Panjang: 38/48/54mm ... Rasio Pencampuran: 98% bengkok + 2% mesh berdasarkan berat

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building

 

Introtuction For Hybrid Type PP Fiber:

PP Hybrid Fiber combines two complementary fiber forms to achieve balanced concrete reinforcement:

Fibrillated pp mesh fibers effectively mitigate early-age shrinkage and thermal cracking. PP twist fiber made from 100% virgin blended copolymer, enhance post-crack flexibility, impact resistance, and overall flexural strength.

This hybrid design ensures excellent dispersion, strong mechanical anchorage, and consistent performance. As a cost-effective and durable substitute for steel fibers, welded wire mesh, and traditional rebar, it delivers synergistic reinforcement across a wide range of secondary structural applications—without the risk of corrosion.

 

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 0  Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 1
                          100% Twisted                                     Hybrid (98% Twisted + 2% Mesh by weight)

 

Applying Instruction For Hybrid Type PP Fiber:

1. Ration design of the fibre concrete: Generally the recommended amount to add to the concrete is more than 2.7kg per sqm(0.3% by volume), reinforcement adding amount is 5.5kg, Compared with adding 47kg of steel fibre, 5.4kg polymer fibre has the same volume ratio to the concrete.

2. Length: 48mm to 54mm for common crack-resistant requirement.

3. Mixer Adoption: Double-axle horizontal compelling mixer is priority.

4. Mixing process: Crushed stones, fibers and sands are put into the mixer in succession. After stirring for two minutes, fiber will fully spread and then add cement and water and stir normally. The addition of materials also can be put into as common concrete, but the stirring time should be properly prolonged to make fiber to be completely mixed .

5. Shaping & Maintenance: There is no special requirement, may along the vibrating time for 30s, The maintenance of the fibre concrete should be done same as the normal concrete.

 

Specification For Hybrid Type PP Fiber:

Index Twisted Bunchy Fibrillated Mesh
Raw Material PP/PE polymer PP
Appearance Twisted Bunchy Mesh form
Elastic Modulus ≥5000Mpa
Length 38/48/54mm ...
Diameter 0.3mm (+/-0 .05) 0.05mm (+/-0 .005)
Melt Point 170℃ 160℃
Density 0.91g/cm3 0.91g/cm3
Break Strength 550Mpa min.
acid&alkali resistance Excellent
 

Application For Hybrid Type PP Fiber:

Industrial and residential floors
Whitetoppings, bridge decks and pavements
Thin walled pre-cast (septic tanks, vaults, walls, etc.)
Mass concrete

 

Packing:

1. The regular packing is 1kg per PE bag, 10kg per plastic woven bag, 16tons in a 40HQ. 

 

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 2  Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 3

2. The other packing is 1kg each PE bag or water soluble paper bag, 11kgs each carton, 9900kgs/1X40`HQ with pallet.

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 4

 

Cetificate:

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 5

 

 

Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 6Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 7Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 8Instead of traditional steel rebar Polypropylene hybrid fibers For Cement Building 9

Rincian kontak
Briture Co., Ltd.

Kontak Person: Linda Qiang

Tel: 0086-13856999452

Faks: 86-551-63517768

Mengirimkan permintaan Anda secara langsung kepada kami (0 / 3000)